Mainline Inspections

Mainline Sewer Televising in MN, ND & SD

Manhole to Manhole.
Every Foot on Record.

Crawler camera inspection of sanitary and storm mains, 6" to 120". Every defect is coded to NASSCO PACP with its footage and position, so you know exactly what is in the line and where.

Street level
MH 1 · start
MH 2
Roots at jointRFJ
Multiple cracksCM
Sag holding waterMWLS
Separated jointJSM
EncrustationDAE
0 ftfootage counter & grade recorded the whole wayMH 2
Mainline sewer televising: Roots, fine, at joint (NASSCO RFJ)
RFJRoots, fine, at joint
Mainline sewer televising: Crack, multiple (NASSCO CM)
CMCrack, multiple
Mainline sewer televising: Water level, sag (NASSCO MWLS)
MWLSWater level, sag
Mainline sewer televising: Joint separated, medium (NASSCO JSM)
JSMJoint separated, medium

Sample run. Frames are real, unedited stills from our own inspections.

6"–120"Sanitary & storm mains
PACPNASSCO certified operators
4KRausch USA crawlers
MN·ND·SDBased in Kensington, MN
When to Televise

When Cities and Engineers Call Us

Mainline televising answers one question: what condition is this pipe in, foot by foot?

Ongoing maintenance programs

Televise a portion of town every year and keep your whole system on record.

New construction acceptance

Catch sags, offsets and debris before the city accepts a new main.

Before and after lining

Find the defects and services before lining, then confirm the finished liner.

Inflow & infiltration studies

Find the joints and cracks letting groundwater into the system.

After a backup or failure

See what caused it and whether the rest of the line is at risk.

Capital planning & bidding

Rank lines by condition and put real data behind repair budgets.

What You Get

A Report You Can Actually Use

Every run comes back as a coded, line-by-line report your engineer can work from, plus the full video.

  • NASSCO PACP coded reportsEvery observation with its code, footage and clock position.
  • 4K still imagesA photo of every defect, right in the report.
  • Footage & grade readoutsDistance and pipe grade recorded the whole way.
  • Video in POSM CentralShared, downloadable and backed up. Program cities see it on Diamond Maps.
Sample PACP report · MH 1 → MH 2Example
Ft Code Observation
0.0 AMH Manhole, start of inspection
9.0 RFJ Roots, fine, at joint
16.7 CM Crack, multiple
31.9 MWLS Water level, sag
68.5 JSM Joint separated, medium
… AMH Manhole, end of inspection
Report still: roots at jointReport still: multiple cracksReport still: sag holding waterReport still: separated joint
Our Equipment

Rausch USA Crawler Systems

Clear video and steady footage counts make the difference between a report you trust and one you redo.

  • 4K pan-and-tilt crawler camerasLook straight at a joint, crack or service connection.
  • Lateral launch on the same crawlerInspect services up to 150 ft from the main. Lateral launch.
  • Cleaning crews on the same jobOur jet/vac trucks clean ahead of the camera.
Rausch USA mainline crawler camera with pan and tilt head
Reviews

What Our Customers Say

5.0Rated 5.0 on GoogleRead our reviews →

“We have used this company for line camera services and jetting. Johnson Jet-Line was always on time and informative!”

Google review

“Johnson Jet-Line was very nice to work with. They were very professional and very prompt at getting our project done. I would recommend them for anyone’s project. Very happy with the service!”

Google review

Mains Need Televising?

Check Televising Mainlines and we will get you a quote. Call 320-965-2374 with questions.

Questions

Mainline Televising FAQ

What is a mainline sewer inspection?

A mainline inspection sends a remote-controlled crawler camera through the sewer main from one manhole to the next. It records every foot of pipe and the operator codes each defect, so you know the condition of the line before you clean, repair, line or replace it.

What size mains can you televise?

Sanitary and storm mains from 6 inches up to 120 inches, in clay, concrete, PVC, ductile and corrugated pipe.

How is the inspection coded?

Our operators are NASSCO PACP certified. Every defect gets a standard PACP code with its footage and clock position, so engineers can rank lines and build repair and lining bid documents straight from the report.

Do you have to clean the line first?

For a usable inspection, usually yes. Grease, roots and debris hide defects and can stop the crawler. Our jet/vac crews clean ahead of the camera, and most city programs schedule cleaning and televising together.

Can you inspect new construction before acceptance?

Yes. We televise new mains for cities, engineers and contractors so sags, offset joints, debris and damaged pipe are caught before the city accepts the line.

Can you televise before and after lining?

Yes. Pre-lining inspections find the defects and service connections, and post-lining video confirms the liner and reinstated services.

What do we get after the inspection?

Line-by-line PACP reports with still images, footage and grade readouts, plus full video. Everything is stored in POSM Central, where it can be shared and downloaded, and program cities see it on Diamond Maps.

Where do you provide mainline televising?

We are based in Kensington, Minnesota and televise sewer mains across Minnesota, North Dakota and South Dakota.

5.0Rated on Google

Connect With Johnson Jet-Line

Worked with us? A Google review helps other cities find a crew they can trust.

Call 320-965-2374 · Mon-Fri 7am-5pm · 24/7 emergency service